MeanWell Power Supply HLP-40H-12(40W 12V) Single Output 40W 12V Switching Power Supply With Active PFC and Dimming

FOB Reference Price:Get Latest Price
50 Piece/Pieces (Min. Order)
Supply Ability:
5,000 Piece/Pieces per Month
Port:
ShenZhen
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
MW
Model Number:
HLP-40H-12
Output Power:
1 - 50W
Output Type:
Single
Input Voltage:
90 ~ 305VAC 127 ~ 431VDC
Output Voltage:
12V
Output Frequency:
47 ~ 63Hz
Output Current:
3.33A
Packaging & Delivery
Packaging Details
MeanWell Box
Delivery Time
3 Days

Specifications

40W 12V Switching Power Supply
Builtin active PFC function
Protection:SC/OV/OC/OT
Support Dimmable Function
3 year warranty

MeanWell Power Supply HLP-40H-12(40W 12V) Single Output 40W 12V Switching Power Supply With Active PFC and Dimming

 

Features :

 

Universal AC input  / Full range (up to 305VAC)
Built-in active PFC function
Protections:Short Circuit / Over Current / Over Voltage/Over Temperature
Cooling by free air convection
Class 2 power unit
Output constant current level adjustable
Three in one dimming function (1 - 10Vdc or PWM signal or resistance)
Suitable for built in LED lighting system
Suitable for dry / damp locations
100% full load burn-in test
3 years warranty
 

Specification:

 

MODELHLP-40H-12
OUTPUTDC VOLTAGE12V
CONSTANT CURRENT REGLON (Note.)7.2 ~ 12V
RATED CURRENT3.33A
RATED POWER40W
RIPPLE & NOISE(max.)150mVp-p
VOLTAGE ADJ.RANGE    10.8 ~ 13.5V
CURRENT ADJ.RANGECan be adjusted by internal potentionmeter or through output cable
2 ~ 3.33A
VOLTAGE TOLERANCE±2.5%
LINE REGULATION±0.5%
LOAD REGULATION±2.0%
SETUP, RISE TIME1500ms, 80ms/115VAC at full load     1000ms,80ms/230VAC at full load     
HOLD UP TIME (Typ.)16ms/230VAC    16ms/115VAC at full load 
INPUTVOLTAGE RANGE90 ~ 305VAC    127 ~ 431VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR (Typ.)PF>0.98/115VAC,PF>0.95/230VAC,PF>0.92/227VAC at full load(Please refer to “Power Factor Characteristic” curve)
EFFICIENCY (Typ.)87%
AC CURRENT (Typ.)0.43A/115VAC   0.24A/230VAC   0.23A/277VAC
INRUSH CURRENT (Typ.)COLD START 50A(twidth=210s measured at 50% Ipeak) at 230VAC   
LEAKAGE CURRENT<0.75mA/277VAC
PROTECTIONOVER CURRENT 95 ~ 108%
Protection type: Constant current limiting,recovers automatically after fault condition is removed
OVER VOLTAGE15 ~ 21V
Protection type: Shut down o/p voltage,re-power on to recover
OVER TEMPERATURE85°C±10°C(RTH2)
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-40 ~ +70°C (Refer to “Derating curve”)
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +80°C, 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/°C (0 ~ 50)°C
VIBRATION10 ~ 500Hz, 2G 12min./1 cycle, period for 72min. each along X,Y,Z axes
SAFETY &SAFETY STANDARDSUL8750,CSAC22.2 No.250.0-0.8(except for 48V,54V),EN61347-1,EN61347-2-13approved;
EMCDesign refer to UL60950-1,TUV EN60950-1,EN60335-1
 WITHSTAND VOLTAGEI/P-O/P: 3.75KVAC  I/P-FG:1.88KVAC  O/P-FG:0.5KVAC
 ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25°C / 70%RH
 EMC EMISSIONCompliance to EN55015,EN61000-3-2 Class C (60% load);EN61000-3-3
 EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11; EN61547,EN55024,light industry level(surge 4KV),criteria A
OTHERSMTBF287.9Khrs min.   MIL-HDBK-217F(25)
DIMENSION147x53x27mm(LxWxH)
PACKING0.2Kg; 72pcs/15.4Kg/1.09CUFT
NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5.Constant current operation region is within 75%-100% rated output voltage.This is the suitable operation region for LED related applications,but please reconfirm special electrical requirements for some specific system design.
6. The power supply is considered as a component which will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7.Direct connecting to LEDs is suggested,but is not suitable for using additional drivers.
8.Length of set up time is measured at cold first s tart.Turning ON/OFF the power supply may lead to increase of the set up time.

 

Technology Data:

 

 

 

PayMent:

 

1. Telegraphic Transfer (T/T)

2. West Union

3. Paypal

4. L/C

 

Products Photo:

 

 

Packing Detail: